Published: CABEQ 19 (2) (2005) 185–190
Paper type: Original Scientific Paper
A. M. Gerrard, O. Misiaczek, D. Hajkova, M. Halecky and J. Páca
Abstract
This paper gives some simple mathematical models for the biofiltration of styrene.
Two different biofilters were used, with diameters of 50 and 100 mm. Granular activated
carbon was used as the packing material (Silcarbon type SC40, particle diameter of 4-6
mm). The styrene level was measured at the inlet, outlet, and intermediate points to give
a mass concentration profile through the reactors. The investigated data were divided
into the three sets of experimental conditions. The changing parameters were the inlet
concentration of styrene and flow rate of air. (However, the mass flow-rate of styrene
was held approximately constant).
The bio-reactions broadly followed first order kinetics. In addition, a modified
Ottengraf’s first order kinetic model was developed and applied to see if it was possible
to get a better fit. We found that values of k = 0.1295 g m-3 and P = –0.0211 s-1 in following equation:
(γg + k / γgi + k) = exp (Ph / ug)
gave a reasonable fit to all the experiments, but that better accuracy could be obtained by using three separate fits for each group of experiments.